Introduction
This guide shows how to change the O-rings on the support valve.
Tools
Parts
- 
                  
                  - 
            Open the side flap and remove the brew group and coffee grounds container. 
- 
            Unscrew the three Torx T10 screws on the cover above the support valve. 
- 
            Take the lid off, now the support valve is open. 
 
- 
            
- 
                  
                  - 
            The support valve is attached with four Torx T10 screws. Unscrew them. 
- 
            Pull the valve forward to remove it. There are two o-rings, do not lose them. Replace the rings later during reinstallation. 
 
- 
            
- 
                  
                  - 
            The seals on the support valve must be closed tightly with each brewing process and are heavily loaded. Replace them. 
- 
            The support valve is closed with a cover with a bayonet lock. Using a flat screwdriver, turn the lid a few degrees counterclockwise and lift it out with a pair of pliers. 
- 
            Check whether the inner parts (sliding piece, valve stem, and spring) can move freely and close tightly. Replace them if necessary. 
 
- 
            