Introduction
Dripping water out of the joint between water reservoir and machine is an annoying issue. The water reservoir seal should be replaced. This ist a very easy fix, you even need not open the Impressa.
Tools
Parts
- 
                  
                  
- 
            
Remove the water reservoir.
 - 
            
Turn the Jura on its side to have access to the bottom plate
 - 
            
The water connector is protected by a plastic cover, which is secured by two plastic rivets.
 - 
            
Use some pliers and squeeze the rivets tightly and push them up until they release.
 - 
            
Carefully pry up the plastic cover.
 - 
            
Insert the new gasket with the flat side facing up.
 - 
            
Give some food-proof lubricant to the new seal and replace it.
 
 - 
            
 
                            
                            Conclusion
                          
                          To reassemble your device, follow these steps in reverse order